1.5 REMOTE Screen

You can establish various setups of the remote terminal from the REMOTE screen.

6

5

8 9

PARALLEL I/O Block

1PARALLEL INPUT indicator

Displays the status of the REMOTE PARALLEL terminal. The PARALLEL INPUT indicator lights in green when the input terminal is ON (0.8V or less).

Refer to the Operating Instructions of the SRP-X700P for the specifications.

2PARALLEL INPUT FUNCTION setup box

You can set the functions of each input channel.

For the setting procedure, refer to “PARALLEL I/O Parameter Setup” on the next page.

1

2

3

4

qa qf q; qs

qd

7

MACHINE CONTROL Block

You can establish various setups to control Sony products through the Control S output terminal. For details of the connection and other procedures, refer to “How to Control AV Equipment from the SRP-X700P” of the SRP-X700P Operating Instruction.

5MACHINE TYPE setup box

Selects the type of machines to be connected to LINE3, LINE4A to LINE4F. The machine types that can be controlled by Control S appear. Select the machine type for the machine to be connected.

3PARALLEL OUTPUT button

Displays the status of the REMOTE PARALLEL terminal. The PARALLEL OUTPUT button lights in green when the output terminal is ON.

Pressing this button enables you to perform the operation test of the equipment connected to the output terminal of REMOTE PARALLEL terminal.

4PARALLEL OUTPUT FUNCTION setup box

You can set the functions of each output channel.

For the setting procedure, refer to “Setting Parameters of PARALLEL I/O” on the next page.

6CTRL S OUTPUT CH setup box

Selects the channel of the Control S output terminal to be connected to the machines of LINE3, LINE4A to LINE4F.

7CONNECTION TYPE setup box

Selects the connection type for each channel of the

6Control S output terminal.

Wired: To connect machines having the Control S input terminal

IR: To connect a supplied IR transmitter to control the Sony’s AV equipment without the Control S input terminal

8TEST machine selector box and 9 CONTROLbuttons

Select the terminal to which the machine to be tested is connected, from the 8 TEST machine selector box. Select the desired test command by pressing any of the 9 CONTROL buttons. You can send the PREV. (previous track), NEXT (next track), STOP (stop), REW. (rewind), PLAY (playback), F.F. (fast forward) or PAUSE (pause) commands.

19