Cleaning Coolant

Reservoir

BIOLOGICAL & POISON

HAZARD!

Use the correct personal protection equipment when handling cutting fluid. Follow Federal, State, and the coolant manufacturer's requirement to safely dispose of the used coolant.

The cavity in the base of the mill can be used as a coolant reservoir if you choose to install a recirculating coolant pump accessory. This reservoir also catches any coolant and debris that falls from the table and through the screens in the base.

Hazards

As some coolant ages, it develops dangerous microbes which eventually proliferate and create a biological hazard. The risk of exposure to this hazard can be greatly reduced by cleaning out the coolant reservoir on a monthly basis or sooner, if needed based on your daily inspection.

The important thing to keep in mind when working with coolant is to minimize exposure to your skin, eyes, and respiratory system by wearing the proper personal protective equipment, which includes splash-resistant safety glasses, long-sleeve gloves, protective clothing, and a NIOSH-approved respirator.

Cleaning

 

Tools Needed

Qty

Hex Wrench 3mm

1

Hex Wrench 10mm

1

Catch Pan

1

To clean out the coolant reservoir:

1.DISCONNECT MILL FROM POWER!

2.Put on personal protective equipment.

3.Remove the coolant reservoir access panel from the rear of the column (see Figure 60).

Screen

Access

Panel

Drain

Plug

Figure 60. Coolant reservoir access panel and drain

plug.

4.Place the catch pan under the drain plug, then remove the plug and allow the fluid to drain into the pan.

5.Clean away debris and grime from the coolant drain screens on the base of the mill.

6.Use rags, scrapers, and cleaning solvent to thoroughly clean out the bottom of the reservoir.

Note: Use a cleaning solvent that is compatible with the type of coolant. For instance, if you are using a water-base coolant, then use a water-base cleaning solvent.

7.When the reservoir is clean and dry, replace the access panel and drain plug.