SpectraLink 8002 Wireless Telephones Configuration and Administration (SIP)

Message

Description

Updating Code

Handset is downloading new software into memory. The number icons at the

 

bottom of the display indicate which file number is currently being downloaded. This

 

message also displays a progress bar. When the progress bar fills the display line

 

the update operation is complete on that file.

 

When the update is complete, the handset displays the extension

 

number, and is ready for use.

Download failure or recovery messages

 

 

The following display messages indicate a failure or recovery

 

 

situation during the download process.

 

 

Message

Description

Server Busy

Handset is attempting to download from a TFTP server that is busy downloading

 

other phones and refusing additional downloads. The handset will automatically

 

retry the download every few seconds.

TFTP

A failure has occurred during the TFTP download of one of the files. (x) = The file

ERROR(x):yy

number which was being downloaded; yy is an error code describing the particular

 

failure. Possible error codes are:

 

01 =

TFTP server did not find the requested file.

 

02 =

Access violation (reported from TFTP server).

 

07 = TFTP server reported "No such user" error. Check the TFTP server

 

 

configuration.

 

16 =

No TFTP server address. Check the TFTP server IP configuration in the

 

 

handset or in the DHCP server.

 

81 =

File put into memory did not pass CRC. The handset will attempt to

 

 

download the file again.

 

FF =

Timeout error. TFTP server did not respond within a specified period of time.

Erase Failed

Download process failed to erase the memory in the handset. This operation will

 

retry.

 

Waiting

Handset has attempted some operation several times and failed, and is now waiting

 

for a period of time before attempting that operation again. This waiting period

 

preserves Battery Pack life.

86