52

RAID 5 (layout) parity-algorithm

It is possible to set one of four algorithms of placement data blocks and parity blocks in matrix. Our default option is left-symmetric, which is the best for large reads. Other recommended value is left-asymmetric.

Left-Asymmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

0

1

2

Parity

3

4

Parity

5

6

Parity

7

8

Parity

9

10

11

12

13

14

Parity

Right-Asymmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

Parity

0

1

2

3

Parity

4

5

6

7

Parity

8

9

10

11

Parity

Parity

12

13

14

Left-Symmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

0

1

2

Parity

4

5

Parity

3

8

Parity

6

7

Parity

9

10

11

12

13

14

Parity

Right-Symmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

Parity

0

1

2

5

Parity

3

4

7

8

Parity

6

9

10

11

Parity

Parity

12

13

14

RAID 6 (layout) parity-algorithm

It is possible to set one from four algorithms of placement data blocks and parity blocks in matrix. Our default option is left-symmetric which is the best for large reads. Other recommended value is left-asymmetric.

Left-Asymmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

0

1

Parity

Parity

2

Parity

Parity

3

Parity

Parity

4

5

Parity

6

7

Parity

8

9

Parity

Parity

Right-Asymmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

Parity

Parity

0

1

2

Parity

Parity

3

4

5

Parity

Parity

Parity

6

7

Parity

8

9

Parity

Parity

Left-Symmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

0

1

Parity

Parity

3

Parity

Parity

2

Parity

Parity

4

5

Parity

6

7

Parity

8

9

Parity

Parity

Right-Symmetric Algorithm

Unit

Unit

Unit

Unit

S0

S1

S2

S3

Parity

Parity

0

1

3

Parity

Parity

2

4

5

Parity

Parity

Parity

6

7

Parity

Parity

Parity

8

9

Page 52
Image 52
Spring Switzerland GmbH Ver. 1.61 manual RAID 5 layout parity-algorithm, RAID 6 layout parity-algorithm