Rev. 0.00
3-129
STARLineModeCommandSpecications
ESC GS / 4 nL nH d1 d2 … dk
[Name] Set user macro 2
[Code] ASCII ESC GS / 4 nL nH d1 d2 ... dk
Hexadecimal 1b 1d 2f 34 nL nH d1 d2 ... dk
Decimal 27 29 47 52 nL nH d1 d2 ... dk
[DenedArea] Thermal : 1 nL 64, nH = 0
1 (nL + nH x 256) 64
dk = (nL + nH x 256)
0 d 255
Slip : -
Validation : -
[Initial Value] Thermal : No user macro 2 setting
Slip : -
Validation : -
[Function]
<Thermal>
Sets user macro 2 for the Auto Logo function.
This setting is registered to non-volatile memory by the ESC GS / W command.
This command is ignored while Auto Logo is executing.
Registers print data in user macro 2.
Maximum 64 bytes of registered data
Note that registering Auto Logo command characters in the user macros is prohibited.
<Slip>,<Validation>
Only setting is valid
Setting is valid after switching to thermal.