Rev. 0.00
3-151
STARLineModeCommandSpecications
3-13) Slip/Validation Function Command Details ESC SI n
[Name] Set slip sensor
[Code] ASCII ESC SI n
Hexadecimal 1B 0F n
Decimal 27 15 n
[DenedArea] Thermal : -
Slip : -
Validation : -
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function]
Three bytes ignored
ESC FF n
[Name] Slip/Validation Function
[Code] ASCII ESC FF n
Hexadecimal 1B 0C n
Decimal 27 12 n
[DenedArea] Thermal : -
Slip : 2 n 5, 50 n 53, (“2” n “5”)
Validation : 2 n 5, 50 n 53, (“2” n “5”)
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function]
<Thermal>
Three bytes ignored
<Slip>
After printing data in the line buffer, the slip paper operation is executed according to the n value.
n Slip Operation
2 to 5
50 to 53
Discharges paper toward the back (the forward direction)
<Validation>
After printing data in the line buffer, the validation printer operation is executed according to the n
value.
n Slip Operation
2 to 5
50 to 53
Discharges paper toward the back (the forward direction)