Rev. 0.00
3-130
STARLIneModeCommandSpecications
ESC GS / 5 n
[Name] Set command character switching method
[Code] ASCII ESC GS / 5 n
Hexadecimal 1b 1d 2f 35 n
Decimal 27 29 47 53 n
[DenedArea] Thermal : 0 n 1
Slip : -
Validation : -
[Initial Value] Thermal : n = 0
Slip : -
Validation : -
[Function]
<Thermal>
Sets command character conversion method for the Auto Logo function.
This setting is registered to non-volatile memory by the ESC GS / W command.
This command is ignored while Auto Logo is executing.
n Setting
0 Does not print command character or logo number continuing after that.
1 Converts the command character and logo number that follows in a space character (0 x 20).
If “/” is specified for the command character, the “/2” embedded in the print data is processed not as
a character string but as a command.
At that time, “/2” is processed as a command so there is no print.
However, “/2” is converted to a space by the n = 1 specification of this command.
<Slip>,<Validation>
Only setting is valid
Setting is valid after switching to thermal.