Rev. 0.00
3-137
STARLineModeCommandSpecications
ESC GS x D nL nH d1 d2 … dk
[Name] PDF417 bar code data setting
[Code] ASCII ESC GS x D nL nH d1 d2 … dk
Hexadecimal 1B 1D 78 44 nL nH d1 d2 … dk
Decimal 27 29 120 68 nL nH d1 d2 … dk
[DenedArea] Thermal : 0 nL 255, 0 nH 255
1 (nL + nH x 256) 1024
0 d 255, 1 k 1024
Slip : -
Validation : -
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function]
<Thermal>
Parameter details
• nL+nH×256: Bar code data count
• dk: Bar code data (max. 1024 data)
When [nL+nH×256] is outside of the defined area, data of [nL+nH×256] bytes is received and dis-
carded.
<Slip>,<Validation>
Only setting is valid
Setting is valid after switching to thermal.
ESC GS x P
[Name] Print PDF417 bar code
[Code] ASCII ESC GS x P
Hexadecimal 1B 1D 78 50
Decimal 27 29 120 80
[DenedArea] Thermal : -
Slip : -
Validation : -
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function]
<Thermal>
Prints bar code data.
If there is unprinted data in the line buffer, this command is executed after printing that data.
Therefore, it is not possible to print with other data in the same line (characters, bit images, bar
codes).
Also, if the following errors occur, this command is ignored.
• An error occurs when generating the bar code by the combination of bar code settings.
• When the generated bar code exceeds the printable PDF417 size.
• When the print data exceeds the currently set print region.
• Bar codes to be printed should always be confirmed through an actual printout.
<Slip>,<Validation>
Four bytes ignored