Rev. 0.00
3-86
STARLIneModeCommandSpecications
[Name] Initialize all memory switches
[Code] ASCII ESC # @ LF NUL
Hexadecimal 1B 23 40 0A 00
Decimal 27 35 64 10 0
[DenedArea] Thermal : -
Slip : -
Validation : -
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function] Initializes all memory switches
Valid when power turned on again, or a reset is applied
ESC # N ? n1 n2 n3 n4 LF NUL[Name] Enquire memory switch settings
[Code] ASCII ESC # N ? n1 n2 n3 n4 LF
Hexadecimal 1B 23 N 3F n1 n2 n3 n4 0A 00
Decimal 27 35 N 63 n1 n2 n3 n4 10 0
[DenedArea] Thermal : n1 = 48 (“0”), n2 = 48 (“0”), n3 = 48 (“0”), n4 = 48 (“0”)
48 ≤ N ≤ 57 (”0” ≤ N ≤ “9”), 65 ≤ N ≤ 72 (”A” ≤ N ≤ “F”), 97 ≤ N ≤ 104 (“a” ≤ N ≤ “h”)
N=85(U)Userdenedregion
Slip : n1 = 48 (“0”), n2 = 48 (“0”), n3 = 48 (“0”), n4 = 48 (“0”)
48 ≤ N ≤ 57 (”0” ≤ N ≤ “9”), 65 ≤ N ≤ 72 (”A” ≤ N ≤ “H”), 97 ≤ N ≤ 104 (“a” ≤ N ≤ “h”)
N=85(U)Userdenedregion
Validation : n1 = 48 (“0”), n2 = 48 (“0”), n3 = 48 (“0”), n4 = 48 (“0”)
48 ≤ N ≤ 57 (”0” ≤ N ≤ “9”), 65 ≤ N ≤ 72 (”A” ≤ N ≤ “H”), 97 ≤ N ≤ 104 (“a” ≤ N ≤ “h”)
N=85(U)Userdenedregion
[Initial Value] Thermal : -
Slip : -
Validation : -
[Function] Sends the memory switch settings.
By specifying N = 85 (“U”), it is possible to read out any user-registered 16 bit data.
• N: Memory Switch Number
Transmission Format
ESC # N ? d1 d2 d3 d4 LF NUL
• N: Memory number
• d1, d2, d3, d4: Memory switch settings