Set horizontal tabstops
MODE ASCII Decimal Hexadecimal
Both <5 SC> “3” rll 27 68 n1 1B4L ,~1
32 <0> n2 0 .q~ . . 00
Cancels all current horizontal tab stops and sets new
tab stops at columns nl, n2, etc. in the current charac-
ter pitch (pica pitch if proportional spacing is currently
selected), where nl, n2,etc. are numbers between 1 and
255. The maximum number of horizontal tab stops
allowed is 32 in Standard mode and 28 in IBM mode.
The tab stops must be specified in ascending order; any
violation of ascending order terminates the tab stop list.
Standard termination is by the <0> control code. To
clear all tab stops, specifj <ESC> “D” <0>.
Resetall tab stops
MODE ASCII Decimal Hexadecimal
IBM <ESC> “R” 27 82 IB 52
Resets the horizontal tab stops to their power-up values
in which atab stop is set every 8columns starting at
column 9. Also clears all vertical tab stops.
Horizontal tab
MODE ASCII Decimal Hexadecimal
Both <ET> 909
Moves the print position to the next horizontal tab stop.
Ignored if there is no next horizontal tab stop on the
current line. Note that when underlining is selected,
spaces skipped by horizontal tabulation are not under-
lined.
Page 119