Lowest

Default

Highest

 

Item

Value

Value

Value

Meaning

 

 

 

 

 

AUTO STOP

OFF

OFF

ON

ON= Auto stop feature enabled.

 

 

 

 

OFF= Auto stop feature disabled.

CSAFE

OFF

OFF

ON

ON=CSAFE communication enabled.

 

 

 

 

OFF=CSAFE communication disabled.

LOCK OUT

OFF

OFF

ON

ON= Treadmill lock out enabled.

 

 

 

 

OFF= Treadmill lock out disabled.

LOCKOUT ID

10000

12345

65535

Treadmill lockout ID.

MINIMUM

0.5/0.8

0.5/0.8

2.0/3.2

Minimum speed in mph (UNITS= English), or km/hr (UNITS= Metric).

SPEED*

 

 

 

 

MAXIMUM

5.0/5.0

10.0/16.0

12.5/20.0

Maximum speed in mph (UNITS= English), or km/hr (UNITS= Metric).

SPEED*

 

 

 

Caution: See Motor Calabration before making any changes.

ACCELERA-

25

25

60

Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr).

TION TIME

 

 

 

 

DECELERA-

20

20

60

Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed.

TION TIME

 

 

 

 

 

 

 

 

 

*When the MINIMUM SPEED or MAXIMUM SPEED parameters are changed, the Treadmill will perform an auto calibration. To termi- nate the auto calibration and return the parameter to its default setting, press the STOP key.

MAINTENANCE MODE

Your Service Representative may need to check accumulated data about the past usage of your treadmill, test its motor and display con- trols, or investigate error messages. For these reasons, your treadmill is equipped with Maintenance Mode. Maintenance Mode includes all of the items available through Manager Mode, plus additional items for Service and Diagnostic use. To enter Maintenance Mode:

1.Press and hold the , , and keys together.

2.A beep will sound and “MAINTENANCE MODE” will display momentarily in the Information Window.

3. Release the remaining keys. “MCI VX.XX CKSM XXXX” will display in the Information Window.

The following keys are available in MAINTENANCE MODE:

Incline Keys: Displays the next and previous parameter, respectively. Keys will repeat if held.

Speed Keys: Adjust the value of the displayed parameter up and down, respectively, in increments of 1 unit or 0.01 unit, as appropriate for the parameter. These keys do not save the new value - see Start Key and Key below.

38

STAR TRAC E SERIES TREADMILL OWNERS MANUAL

Page 48
Image 48
Star Trac 620-7920 manual Maintenance Mode