3-5 Initial Set-up

This section will discuss the mechanical setup and control system setup of the rate monitor system. After reading this section, you should be familiar with the mechanical setup and the electronic control setup of the rate monitor.

Mechanical Set-up

Weigh Hopper Installation

It is necessary to install the weigh hopper. Remove the weigh hopper from the shipping box and install it onto the load cell bracket. Two provided thumbscrews are used to secure the weigh hopper to the load cell bracket.

Figure 12: Picture of Weigh Hopper

Note: THE WEIGH HOPPER ASSEMBLY MUST HANG FREELY AND BE FREE FROM FRICTION, WITH NO MECHANICAL OBSTRUCTIONS OTHER THAN THE LOAD CELL ITSELF.

It is very important the tube stub of the weigh hopper does not touch the supplied dust ring. It is also important the flange of the weigh hopper be completely flush with the load cell bracket.

Extruder RPM connection

The supplied inductive proximity switch must be mounted to accurately read the Extruder’s RPM. If the optional Ethernet module was purchased, the extruder’s speed may be reported to the controller via communications (see communications section at the end of this manual,

NOT AVAILABLE FOR GH-F UNITS).

The proximity switch must be mounted securely, and read the actual RPM of the extruder. Supplementary documentation on this proximity switch is provided from its manufacturer.

To wire the supplied inductive proximity switch the PLC enclosure, please refer to the supplied wiring schematics.

Chapter 3: Installation

27 of 60

Page 27
Image 27
Sterling 882.00722.00 manual Initial Set-up, Mechanical Set-up, Weigh Hopper Installation, Extruder RPM connection