Pneumatic Slide Gate below surge hopper

The surge hopper can be equipped with a pneumatic slide gate in lieu of the air cylinder and urethane dump cone. The knife gate is opened and closed by the PLC. A 24 VDC solenoid is used to open and close the knife gate.

WARNING! Slide gates create a pinch-point hazard

Low Level Proximity Sensors

Detects material supply problems before rate monitor hoppers are empty. A 24VDC capacitive proximity switch is utilized for this option. The proximity switch is wired directly into the PLC enclosure. If there is a material supply problem, a visual alarm is activated.

2-5 Safety Features

This section includes information on safety devices and procedures that are inherent to the rate monitor system. This manual is not intended to supersede or alter safety standards established by the user of this equipment. Instead, the material contained in this section is recommended to supplement these procedures in order to provide a safer working environment.

Chapter 2: Functional Description

23 of 60

Page 23
Image 23
Sterling 882.00722.00 manual Safety Features, Pneumatic Slide Gate below surge hopper, Low Level Proximity Sensors