Enter the long password “3145348” and press “Enter”. The factory setup section displays the “Engineering Only” screen. The screen similar to that shown below should be displayed and use the keystrokes described herein to change or toggle the parameters.

Figure 68: Typical Engineering Only Setup Screen

Go back to

Setup

Directory

Select the desired menu to advance to the screens listed below. The exit to the “Setup” screen select “Done”

Figure 69: Typical Advanced Weight Options Screen

Advanced Weight Options Screen

*Only adjust the weight filter upon request by service

*Increase the “Time to settle hopper after reload valve has shut” if the hopper needs more time to settle after reloading

*Increase “No flow timer” and decrease “No flow bits” to reduce nuisance “no flow” alarms. Set to “0” will disable this alarm.

Figure 70: Typical WTP Alogorithm Options

WTP Algorithm Options Screen

The method that is used to calculate the measured lbs/hr is entirely adjustable to fit any application. The three methods that can be used is “Extruder Pulse Count Method”, “Percent of Hopper Method”, or “Full hopper Method”. You cannot use the “Extruder Pulse Count Method” if you are writing the extruder speed through communications instead of using our inductive proximity switch.

Chapter 7: Appendix

51 of 60

Page 51
Image 51
Sterling 882.00722.00 manual Typical Engineering Only Setup Screen