initially displayed is the weight which would result in a motor speed of 25%. The valid range of values would then be ¼ to 2.5 times this initial value.

“DD” Pellet Discs

Disc

Calibration Number

No. of Pockets

Disc Thickness

 

 

 

 

DD 30-030672

1.75

72

3 mm

 

 

 

 

DD 30-051040

5.00

40

 

 

 

 

5mm

DD 30-051725

8.00

25

 

 

 

 

DD 30-051818

15.00

18

 

 

 

 

 

“DT” Pellet & Regrind Discs

Disc

Disc

Calibration

No. of

Thickness

Number

Pockets

 

 

 

 

 

 

DT 30-101820

32.00

20

 

 

 

 

10 mm

DT 30-102025

 

 

(“Sure-shot” - 20

 

20 Oval

 

 

 

oval holes)

38.00

 

 

 

 

 

20mm

DT 30-203012

100.00

12

 

 

 

DT 30-204010

175.00

10

 

 

 

 

 

“DP” Powder Discs

Disc

Calibration

Disc

Number

Thickness

 

 

 

 

DP 30-050940

17.00

5mm

 

 

 

 

 

DP 30-250940

8.00

2.5mm

 

 

 

Additive Sample weighing.

Weighing samples of additive provides for more precise control of feed rate. Up to 5 samples can be weighed. All weights entered are averaged to arrive at a value to be used during operation. The weighing process may be skipped altogether, in which case the calibration weight is used for calculations of feed rate.

Weight Calibration.

The final step of recipe setup is weight calibration. This procedure is common to all types of presses supported. After entering the calibration weight, pressing the “Next” button displays the following screen:

882.01749.00

27 of 93

Page 27
Image 27
Sterling 882.01749.00 manual Weight Calibration, Disc Calibration Number Thickness