Sterling 882.01749.00 manual DD Pellet Discs, Screw Recovery Time, Calibration weight

Models: 882.01749.00

1 93
Download 93 pages 30.31 Kb
Page 16
Image 16

Screw Recovery Time.

The screw recovery time is the estimated screw recovery time, and is used as the initial value for validating the recipe. Actual screw recovery times as measured by the presence of the screw recovery signal, are used to fine-tune the feed rate during operation. The estimated time must be at least ½ of the actual recovery time. If less than ½, the feeder will interpret the recovery signal as a purge cycle.

Calibration weight.

Calibration weight is determined from the following tables, and is dependant on the disc installed in the feeder. This weight is the amount of standard density material dispensed by the feeder during one revolution of the disc. This weight is used as the initial value for recipe validation and feed rate calculation. If samples are not weighed as described in the next section, this value is used during operation. The weight can be entered in ounces or grams. The unit of measure is changed by pressing the units button at the middle right of the screen. Changing the unit of measure will NOT change the value displayed on the screen. The value initially displayed is the weight which would result in a motor speed of 25%. The valid range of values would then be ¼ to 5 times this initial value.

“DD” Pellet Discs

Disc

Calibration Number

No. of Pockets

Disc Thickness

 

 

 

 

DD 30-030672

1.75

72

3 mm

 

 

 

 

DD 30-051040

5.00

40

 

 

 

 

5mm

DD 30-051725

8.00

25

 

 

 

 

DD 30-051818

15.00

18

 

 

 

 

 

882.01749.00

16 of 93

Page 16
Image 16