Sterling 882.01749.00 manual Removing the DD Disc and Cleaning the Dosing Module

Models: 882.01749.00

1 93
Download 93 pages 30.31 Kb
Page 71
Image 71

4-3 Removing the “DD” Disc and Cleaning the Dosing Module

Dismantling the Dosing Module

1.Switch the control unit “Off” with the “On/Off” switch.

2.Disconnect the power supply.

3.Open the toggle latches on the dosing motor.

4.Remove the dosing unit from the dosing motor.

5.Empty the dosing module.

6.Open the profile clamp on the dosing hopper.

7.Remove the dosing hopper from the dosing module.

8.Dismantle the dosing module and remove the shear (D) as described above in 5.2.

9.Loosen and remove the two M6 x 30 socket screws (C) on top of the dosing disc (A).

10.Remove the center M6 x 12 socket screw (B) and replace with an M6 x 30 or 60 screw.

11.Lift the dosing disc (A) from the dosing unit housing (B) by tightening this screw.

12.Clean the shear plate with a cotton cloth.

13.Clean the dosing hopper and the dosing disc in soapy water.

14.The dosing unit housing may also be cleaned with a soft cloth, keeping liquids out of the bearings.

882.01749.00

71 of 93

Page 71
Image 71
Sterling 882.01749.00 manual Removing the DD Disc and Cleaning the Dosing Module, Dismantling the Dosing Module