Sterling 882.01749.00 manual Level Sensor Adjustment Screw

Models: 882.01749.00

1 93
Download 93 pages 30.31 Kb
Page 64
Image 64

LED Yellow (Station)

LED Green (Level Probe)

 

 

 

 

 

 

 

on: Station Filled

on: Power Supply Available

 

 

 

 

 

 

 

off: Station Emptied

off: Power Supply Not Available

 

 

 

 

 

 

 

 

npn: Normally Closed

 

 

 

 

 

 

npn: Normally Open

 

pnp: Normally Open 1

 

 

 

 

 

0 pnp: Normally Closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blind Lid

Trim-pot with

Protective Screw

Plastic Screw M3

Cable

 

Level Probe

Figure 7. Level Sensor Adjustment Screw

4. Turn the trim-pot until the yellow control lamp just switches off.

NOTE: Turning the trim-pot to the left decreases the switching sensitivity, and turning it to the right increases the sensitivity.

5.Fill the dosing station until the level probe is two-thirds covered. The yellow control lamp should now switch on again. If not, repeat Step 4.

6.Reinstall the plastic screw (M3).

NOTE: The sliding switch under the cover must be set on “0”.