Electrical Problems

7-2

Electrical Problems

 

 

 

 

Problem

Possible Causes

Possible Remedies

Machine stops for no

Safety switch has stopped power

Check that the knobs that operate

apparent reason

 

the safety switch are tightened

 

 

 

Electric motor does not

No power

Check fuses

start

 

 

 

 

 

Overload failure

Check amperage of electric motor

 

 

 

Check and replace

 

 

Safety switch not working

 

 

 

 

Empty cutting chamber

 

 

Cutting chamber too full

 

Motor starts but does not

Excessive drive belt tension

Check belt tension and adjust

speed up or take a load

 

 

 

 

Motor connected to power source

Reconnect correctly

 

 

incorrectly

 

 

 

Defective starter winding

Check current in each phase. If

 

 

 

substantial difference between

 

 

 

phases, contact motor manufacturer

 

 

 

Motor starts, but does not

Bearing excessively worn

Replace bearings

gain speed

 

 

 

 

 

Cutting chamber full

Empty cutting chamber