5.Enter the number of minutes (between 0 and 99) that you want the horn to stay off. If you want the horn to stay on as long as the alarm persists, leave the setting at 0. If you want the horn to stay off until a new alarm occurs, enter 99 in the keypad. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears and the new setting appears under Horn Silence.

Setting Up Pump Staging

To avoid an excessive power demand at your facility when the conveying system starts up, you can stagger the times at which pumps start. Whenever a demand would cause two pumps to start simultaneously, your choice for pump staging sets the delay between the start of one pump and the start of the next. The factory default is a delay of three seconds. You need to change this setting only if this delay is too long or too short for your facility.

To set the delay between the start of one pump and the next, complete the following steps:

1.Go to the “System Setup” screen by touching the Menu button on any screen. Then touch System Setup. The “System Setup” screen will pop up.

2.Touch the Pump Staging button. A keypad pops up.

3.Enter the number of seconds (between 0 and 99) for the length of the delay between the

start of one pump and the next. Use (Backspace Key) to erase any mistakes.

Use (Enter Key) to enter the value. The keypad disappears, and the new setting appears under Pump Staging.

Setting Up Touch Switch Delay

During operation, the controller normally displays the “Station Status” screen or the “Pump Status” screen, showing the current status of all stations or pumps. Briefly touching the icon for a station or pump toggles between taking it offline (disabling it) and putting it online (enabling it). Touching the icon and holding it takes the user into the controller’s menu system. The setting for button delay determines how long the user must keep an icon touched before a menu appears. The factory default is 1.5 seconds. You need to change this setting only if you find that users are having difficulty with the current setting.

To change the touch switch delay, complete the following steps:

1.Go to the “System Setup” screen by touching the Menu button on any screen. Then touch System Setup. The “System Setup” screen will pop up.

2.On the System Setup screen (Figure 4), touch the Button Delay button. A keypad pops up.

3.Enter the number of seconds (between 0 and 99) for the button delay. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears, and the new setting appears under Button Delay.

2–Pump 20-Station Controllers