6.Enter the total number of pumps (1-2) to be controlled by the system. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears, and the new setting appears under Pumps Present.

Setting Up Alarm Duration

When an alarm occurs, a horn sounds and a strobe light flashes at each installed central alarm. An alarm banner screen appears. An alarm message and Alarm Silence button are on the banner. Touching this button silences the horn and turns off the lights for configurable periods of time and causes the alarm banner to disappear. You can set different lengths of time for keeping the horn silent and keeping the light turned off. If a new alarm occurs, the horn sounds and the light turns on again.

To set the lengths of time for suppressing the alarm strobe and horn, complete the following steps:

1.Go to the “System Setup” screen (Figure 5) by touching the Menu button on any screen. Then touch System Setup. The “System Setup” screen will pop up.

2.On the “System Setup” screen (Figure 5), touch the Strobe Suppress button. A keypad pops up with an entry of 0.

Figure 5: System Setup Screen

Stations

19-20

3.Enter the number of minutes (between 0 and 99) that you want the strobe lights to stay off. If you want the light to stay on as long as the alarm persists, leave the setting at 0. If you want the light to stay off until a new alarm occurs, enter 99 in the keypad. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears and the new setting appears under Strobe Suppress.

4.On the “System Setup” screen (Figure 4), touch the Horn Silence button. A keypad pops up with an entry of 0.

Hopper Loaders with/without Sight Glasses

16

Page 21
Image 21
Sterling Plumbing scc2 specifications Setting Up Alarm Duration, System Setup Screen