Name

Description

Options

Default

Alarm Options

 

 

 

No convey

When this option is enabled, the controller issues

disabled,

disabled

 

a “no convey” alarm if it has repeatedly attempted

enabled

 

 

to convey material to the station but the flapper

 

 

 

never opened during the dump delay. (The

 

 

 

number of attempts is controlled by the next

 

 

 

setting.)

 

 

 

Usually this option should be enabled. At times,

 

 

 

you may wish to disable it during operation as a

 

 

 

stopgap measure for dealing with an alarm.

 

 

# attempts before

Number of attempts before alarm: the number of

1–99

3

alarm

times the controller will attempt to convey material

 

 

 

to a station before it issues a “no convey” alarm.

 

 

 

The setting for this option depends on (a) how

 

 

 

much material your injection mold uses to make

 

 

 

each part compared with the capacity of the

 

 

 

receiver and (b) how important it is to keep your

 

 

 

injection mold from running out of material and

 

 

 

shutting down. A higher setting will give you fewer

 

 

 

alarms, at the risk of emptying the receiver without

 

 

 

warning. A lower setting will give more frequent

 

 

 

alarms, at the risk of disrupting operations

 

 

 

unnecessarily.

 

 

2–Pump 20-Station Controllers

Configurable Settings/Defaults

41 of 51

Page 46
Image 46
Sterling Plumbing scc2 specifications Pump 20-Station Controllers Configurable Settings/Defaults