4.When you are finished reviewing the information, touch Return. The “Help Menu” screen opens.

5.Touch Menu to return to the “Menu” screen.

The following table explains the status represented by each color at the “Station Status” screen.

Color

Label

Description

Gray outline

Offline

Station is not enabled. The controller ignores any demands or

 

 

alarms.

Blue

Ready

Station is enabled and idle (full).

Yellow

Demand

Station requires material.

Green

Loading

Station is being loaded with material.

Light blue

Dumping

Station is dumping material into its receiver.

Green, blinking

Priority

Station is in priority convey mode. Its pump will be temporarily

 

 

dedicated to filling it as soon as possible.

Red, blinking

Alarm

Station is in alarm.

Red outline, blinking

Critical

Station is in critical alarm. The controller has disabled the station

 

 

until the alarm is cleared.

Additional basic information about each station (convey time, dump delay, and pump assignment) is available at the “Station Operator” screen. See page 314 for details.

Detailed configuration settings for each station are available at the “Station Setup” screen. See page 40 for details about each of these settings.

Reviewing Pump Status

The “Pump Status” screen is the counterpart of the “Station Status” screen. To reach the “Pump Status” screen from any other screen, touch Menu on the right-hand side of the screen, and then touch Pumps. The “Pump Status” screen appears.

Figure 14: “Pump Status” Screen During Operation

Stations

19-20

The status of each pump is color-coded. You can see an explanation of each status by using the online help. To do so from this screen, complete the following steps:

Hopper Loaders with/without Sight Glasses

28

Page 33
Image 33
Sterling Plumbing scc2 specifications Reviewing Pump Status, Pump Status Screen During Operation