Figure 17: Pump Setup Screen

The box labeled x Hours Resettable shows the running time since the last reset. The box labeled x Hours shows total running time.

To reset the resettable meter, touch Hour Meter Reset. The time above Hours Resettable changes to 0.

Transferring Stations to a Standby Pump

If a pump fails, you can transfer all of the controller’s station assignments for that pump to a standby pump. To do this, you must disable (take offline) both the source pump and the standby pump, and the standby pump must have no stations already assigned to it.

The transfer operation at the controller’s touch screen merely changes the pump assignment for every station on the failed pump. It does not transfer any pump settings for auto shutdown delay, alarms, or blow-back to the standby pump. Mechanical connections must be changed manually.

To transfer stations from a pump to a standby pump, complete the following steps:

1.At any screen, touch Menu, and then touch Pumps. The “Pump Status” screen appears.

2.Both the source pump and the standby pump must be offline. If either pump is any other state, disable it by touching its icon briefly. The icon becomes black with a gray outline.

3.Move the vacuum hose from the failed pump to the standby pump, and carry out any other mechanical procedures needed to use the standby pump.

4.At the “Pump Status” screen, touch and hold the icon for any pump until the “Pump Setup” screen appears.

5.At the “Pump Setup” screen, touch Transfer Stations To Standby Pump. The “Transfer to Standby Pump” screen opens:

Hopper Loaders with/without Sight Glasses

34

Page 39
Image 39
Sterling Plumbing scc2 specifications Pump Setup Screen, Transferring Stations to a Standby Pump