MODEL 427G / 427RG SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause inter- ruption of operation.
The electrical outlet must be positioned with the grounding prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS |
|
Electrical Supply | 115 VAC, 60 Hz |
Service | 15 amp |
Receptacle |
CAUTION
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.
WARNING
Do not use an extension cord,
Preparation
Uncrate the unit and inspect for damage. Remove the wood base and discard shipping bolts and brackets. Remove and recycle packing materials. Do not discard the kickplate, anti- tip bracket and hardware.
IMPORTANT NOTE: For model 427RG, the upper drawer has a control cable that must be disconnected before removing the drawer. Refer to the illustration below.
Control cable (model 427RG).
| LEFT SIDE |
| OF OPENING |
21/2" |
|
(64) | 13" (330) |
| |
| 41/2" |
| (114) |
1/4" | FLOOR |
(6) |
|
Electrical supply location.