MODEL 427G / 427RG INSTALLATION
Placement
CAUTION
Before moving the unit into position, secure the door/ drawers closed and protect any finished flooring.
Use an appliance dolly to move the unit near the opening. Front and rear leveling legs can be adjusted from the front once the unit is positioned.
If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power.
If the unit will be connected to a home security system, run lead wires through the compressor compartment prior to positioning the unit. Refer to page 17. Once the unit is in position, wiring connection can be completed from the front.
Plug the power cord into the grounded outlet, then slide the unit into position. Verify the
Alignment
LEVELING
Once the unit is in position, height adjustment can be made from the front. Using a standard screwdriver, turn front leveling legs clockwise to raise the unit or counterclockwise to lower. Using a Phillips drive, turn rear adjustment screws clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill (18 revo- lutions equals 1/16" of height adjustment). Do not turn the rear leveling legs by hand. Refer to the illustrations below.
Level the unit to the floor, not surrounding cabinetry. This could affect the operation of the unit, such as door closing. When the unit is properly leveled, door/drawer adjustments are less likely to be necessary.
Secure the unit in place using the side mounting clips and #8 x 1/2" screws provided.
WARNING
To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.
Front adjustment. | Rear adjustment. |