MODEL 424G / 424FSG SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault cir- cuit interrupter (GFCI) is not recommended and may cause interruption of operation.
IMPORTANT NOTE: The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.
ELECTRICAL REQUIREMENTS |
|
Electrical Supply | 115 VAC, 60 Hz |
Service | 15 amp |
Receptacle |
|
WARNING
Do not use an extension cord,
| LEFT SIDE |
| OF OPENING |
2" | 151/2" |
(51) | (394) |
| 3" (76) |
| FLOOR |
Electrical supply location.
Preparation
To operate properly, the door must open a minimum of 90°. Use a minimum 3" (76) filler in corner installations to assure a 90° door opening.
Uncrate the unit and inspect for damage. Remove and recycle packing materials. Do not discard the kickplate, anti- tip bracket, hardware and the leveling legs which hold the wood base to the bottom of the unit.
subzero.com 5