Sub-Zero 427G / 427RG, WS-30, 424G / 424FSG manual Dual Installation, Electrical

Models: 424G / 424FSG 427G / 427RG WS-30

1 92
Download 92 pages 41.12 Kb
Page 22
Image 22
Dual Installation

MODEL WS-30 SITE PREPARATION

Dual Installation

If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 2" (51) filler strip is recommended between units. Dual installations without a filler strip can only be accom- plished using two units with opposite hinges. Refer to the illustrations below.

Dual installation kits are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. For ques- tions regarding the installation, call Sub‑Zero customer care at 800-222-7820.

Electrical

Installation must comply with all applicable electrical codes.

The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause inter- ruption of operation.

ELECTRICAL REQUIREMENTS

 

Electrical Supply

115 VAC, 60 Hz

Service

15 amp

Receptacle

3-prong grounding-type

Manual background CAUTION

WITHOUT FILLER STRIP

FILLER STRIP

The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.

Manual background WARNING

Do not use an extension cord, two-prong adapter or remove the power cord ground prong.

Opposite hinges.

Same side hinges.

7"

E

(178)

 

 

6"

(152)

751/2" (1918)

 

FROM FLOOR

 

RIGHT SIDE

 

OF OPENING

 

Electrical supply location.

22 Sub-Zero Customer Care 800.222.7820