MODEL
Dual Installation
If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 2" (51) filler strip is recommended between units. Dual installations without a filler strip can only be accom- plished using two units with opposite hinges. Refer to the illustrations below.
Dual installation kits are available through an authorized
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause inter- ruption of operation.
ELECTRICAL REQUIREMENTS |
|
Electrical Supply | 115 VAC, 60 Hz |
Service | 15 amp |
Receptacle |
CAUTION
WITHOUT FILLER STRIP |
FILLER STRIP |
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.
WARNING
Do not use an extension cord,
Opposite hinges. | Same side hinges. |
7" | E | |
(178) | ||
| ||
| 6" | |
(152) | ||
751/2" (1918) |
| |
FROM FLOOR |
| |
RIGHT SIDE |
| |
OF OPENING |
|
Electrical supply location.
22