MODEL WS-30 INSTALLATION

Completion

HOME SECURITY CONNECTION

If the unit will be connected to a home security system, make connections to the leads shown in the illustration below. Refer to the following color codes:

Normally open contacts—white with red stripe wire.

Normally closed contacts—white with blue stripe wire.

Common—gray with white stripe wire.

Use the spade terminals or wire nuts provided to make proper wiring connections.

Manual background CAUTION

The alarm circuit in the unit is intended as a low- voltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

HOME SECURITY

LEADS

Home security connection.

ANCHORING

After the unit has been leveled and door adjustment com- pleted, anchor the unit to the opening to ensure a proper fit and secure installation.

To anchor the top of the unit, open the grille and install the screws provided, through the grille frame into cabinetry. There are several hole locations. Refer to the illustration below. Check for proper door clearance by opening the door.

To anchor the bottom of the unit, drive a screw through the side hole inside each roller base assembly. The screw will need to go in at an angle to attach properly. Refer to the illustration below. Additional material may be needed behind the cleat to ensure sufficient anchoring.

Manual background CAUTION

If the screws provided are not suitable for the installa- tion, use adequate screws.

ANCHORING

SCREWS

ANCHORING

SCREW

Top anchoring.

Bottom anchoring.

30 Sub-Zero Customer Care 800.222.7820