TABLE 2-3Server LEDs

LED Name

Function

Location

Color

Status

 

 

 

 

 

Memory

Identifies failing

At the front of each

Amber

On = fault

DIMM

DIMM module

DIMM location on

 

 

fault (1 - 6)

 

main board

 

 

POST

Displays boot 80

Left rear of main

Each LED

See “POST Progress Code LED Indicators” on

LEDs

POST codes

board

can be off,

page 2-30for POST code LED details.

(1 - 4)

 

 

green, red,

 

 

 

 

or amber

 

Fan fault

Identifies Sun

On Sun StorEdge 5310

Amber

On = fault

(1 - 4)

StorEdge 5310

NAS fan module

 

 

 

NAS fan failure

board

 

 

CPU 1 and

Identify CPU

Back corner of

Amber

On = fault

2 fault

failure

processor socket on

 

 

 

 

main board

 

 

5V

Identify 5V

Front left on main

Green

Green = 5V standby power on

standby

standby power

board

 

 

 

on state

 

 

 

Main

Identifies power

Front panel

Green

Off = power is off

power

state of the

 

 

On = power is on

LED

server

 

 

 

 

 

 

 

 

2.5.1Front Panel LEDs and Pushbuttons

The front panel contains the pushbuttons and LEDs shown in Figure 2-1.Note that the illustration has the bezel removed.

2-12Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

Page 58
Image 58
Sun Microsystems 5310 NAS manual Front Panel LEDs and Pushbuttons, Post

5310 NAS specifications

Sun Microsystems, known for its innovative computing solutions, launched the Sun 5310 Network Attached Storage (NAS) system, which marked a significant advancement in the realm of storage solutions in the early 2000s. The 5310 NAS was designed to provide high-performance, reliable, and scalable storage tailored for enterprise environments.

One of the standout features of the Sun 5310 NAS is its file-serving capabilities, which support multiple protocols, notably NFS (Network File System) and CIFS (Common Internet File System). This dual-protocol support allowed organizations to seamlessly integrate the NAS into diverse IT ecosystems, facilitating interoperability between UNIX, Linux, and Windows systems. The enhanced file-sharing capabilities made it an ideal solution for businesses with mixed operating environments.

The Sun 5310 NAS incorporates cutting-edge technologies to ensure high availability and data integrity. The system utilized a RAID (Redundant Array of Independent Disks) technology, providing various RAID levels to protect against data loss while optimizing performance. Additionally, the device featured hot-swappable drives, enabling maintenance and upgrades with minimal downtime, a crucial factor for business continuity.

Equipped with advanced management software, the Sun 5310 NAS offered users an intuitive interface for monitoring storage health and performance. This software included comprehensive reporting functionalities that allowed IT administrators to oversee usage patterns and capacity planning efficiently.

Scalability was another defining characteristic of the Sun 5310 NAS. The system could easily expand with additional storage modules, accommodating the growing needs of an organization without the necessity for complete system overhauls. This flexibility ensured that businesses could adapt their storage solutions to meet evolving data storage needs without incurring significant costs or disruptions.

In terms of performance, the Sun 5310 NAS featured high I/O throughput achieved through its robust hardware architecture and optimized file serving capabilities. This performance baseline was crucial for organizations that relied on heavy data workloads and required rapid access to information.

In summary, the Sun 5310 NAS from Sun Microsystems embodied a forward-thinking approach to network storage, blending reliability, scalability, and multi-protocol support. Its user-friendly management software, combined with the robustness of RAID technology and hot-swappable drives, made it a preferred choice for enterprises looking to streamline their storage infrastructure while safeguarding critical data.