Sun Microsystems X4150 manual Enable the properties or triggered actions for the sensor

Models: X4150

1 150
Download 150 pages 45 Kb
Page 100
Image 100

3.Display EventFilterTable1 by entering the following command: /SP/AgentInfo/PEF/EventFilterTable1–>show

The result of executing the show command appears:

/SP/AgentInfo/PEF/EventFilterTable1

Targets:

Properties:

Status = enable

SensorType = All

PowerCtrl = disable

DiagnosticInterrupt = disable

SendAlert = disable

SendMail = disable

Target Commands: show

set

Next, set the sensor type. There are six values for the sensor type: All, Memory, Processor, Temperature, Voltage, and Fan.

4.Use the set command to configure the sensor type. set sensortype=value

For example, to set the temperature sensor, enter: /SP/AgentInfo/PEF/EventFilterTable1–> set sensortype=Temperature

5.Enable the properties or triggered actions for the sensor.

6.Use the set command to enable (or disable) actions. For example, to set the sendalert and sendmail actions, enter:

/SP/AgentInfo/PEF/EventFilterTable1–> set sendalert=enable

/SP/AgentInfo/PEF/EventFilterTable1–> set sendmail=enable

84 Sun Fire X4150 Server Embedded Lights Out Manager Administration Guide • September 2007

Page 100
Image 100
Sun Microsystems X4150 manual Enable the properties or triggered actions for the sensor