A similar panel is repeated for each monitored entity.

Monitoring Voltages

To Monitor Voltage

From the Sensor Reading tab, click the Voltage tab.

The Voltage screen appears. The Voltage screen displays the critical and noncritical thresholds, the actual sensor reading, and the status for the nine monitored DC system voltage lines. The Sensor Reading value represents the actual voltage reading for that sensor. TABLE 3-14shows a sample from the Voltage screen. The sample is for the Vcc 12V line:

TABLE 3-14Sample of the Voltage Monitor Screen

Description

Vcc 12V

 

 

Lower noncritical threshold is readable:

11.999

Lower critical threshold is readable:

10.821

Upper noncritical threshold is readable:

12.837

Upper critical threshold is readable:

13.215

Sensor Reading:

12.081

Status:

ok

 

 

Viewing and Managing the Event Log

The Event Logs screen allows you to view and manage the system event log (SEL). The SEL is a record of event occurrences. To record events in the SEL, you must have previously determined which events require logging. See “Configuring Platform Event Filters” on page 27.

24 Sun Fire X4150 Server Embedded Lights Out Manager Administration Guide • September 2007