SUPERSERVER 6014P-T/6014P-TR User's Manual

6.Press Enter.

7.Read the warning message as shown on the screen below.

8.Make sure that you have selected the correct disk drives to initialize. If cor- rect, type Y to continue.

Rebuilding Arrays

Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.

If an array build process (or initialization) is interrupted or critical with one member missing, you must perform a rebuild to optimized its functionality. For a critical array rebuild operation, the optimal drive is the source drive.

Note 2: If no spare array exists and a hard disk drive fails, you need to create a spare before you can rebuild an array.

To Rebuild an array:

1.From the Main Menu, select Manage Arrays. From the list of arrays, select the array you want to rebuild.

2.Press Ctrl+R to rebuild.

B-14

Page 114
Image 114
SUPER MICRO Computer 6014P-TR user manual Rebuilding Arrays, To Rebuild an array