SBA-7222G-T2 Blade Module User’s Manual

A-2 BIOS POST Codes

This section lists the POST (Power-On Self-Test) codes for the AMI BIOS. POST codes are divided into two categories: recoverable and terminal.

Recoverable POST Errors

When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem. BIOS may also issue one of the following beep codes:

One long and two short beeps – video configuration error

One repetitive long beep – no memory detected

Terminal POST Errors

If a terminal type of error occurs, BIOS will shut down the system. Before doing so, BIOS will write the error to port 80h, attempt to initialize video and write the error in the top left corner of the screen.

The following is a list of codes that may be written to port 80h.

Uncompressed Initialization Codes

The uncompressed initialization checkpoint codes are listed in order of execution in table Table A-2.

 

Table A-2. Uncompressed Initialization Error Codes

 

 

Post Code

Description

D0h

The NMI is disabled. Power on delay is starting. Next, the initialization

code checksum will be verified.

 

 

 

D1h

Initializing the DMA controller, performing the keyboard controller BAT

test, starting memory refresh and entering 4 GB flat mode next.

 

D3h

Starting memory sizing next.

 

 

D4h

Returning to real mode. Executing any OEM patches and setting the

Stack next.

 

 

Passing control to the uncompressed code in shadow RAM at

D5h

E000:0000h. The initialization code is copied to segment 0 and control

 

will be transferred to segment 0.

 

 

 

Control is in segment 0. Next, checking if <Ctrl> <Home> was pressed

D6h

and verifying the system BIOS checksum. If either <Ctrl> <Home> was

pressed or the system BIOS checksum is bad, next will go to checkpoint

 

 

code E0h. Otherwise, going to checkpoint code D7h.

 

 

A-4

Page 64
Image 64