13 TROUBLESHOOTING
If your receiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM | POSSIBLE CAUSE | SOLUTION | REF. |
|
|
|
|
No power comes on. | • The installed batteries are exhausted. | • Charge the batteries or place new dry cell batter- | p. 8 |
| (A slight current flows in the circuits even when | ies in the battery case. |
|
| the power is OFF.) | (Remove the batteries if you will not be using the |
|
|
| receiver for a long time.) |
|
| • The batteries have been installed in reverse po- | • | p. 8 |
| larity. |
|
|
|
|
|
|
No audio is output. | • [VOL] is turned to the minimum position. | • Turn [VOL] to a suitable level. | p. 10 |
| • Earphone or headphone is connected. | • Disconnect the earphone or headphone. |
|
| • The [SQL] is turned too far clockwise. | • Turn the [SQL] counterclockwise. | p. 11 |
| • VSC function is activated. | • Release the VSC function. | p. 38 |
|
|
|
|
Weak reception, excessive | • Not centered on the frequency. | • Set to the center frequency using a small tuning | p. 13 |
distortion or too much |
| step. |
|
noise. | • Wrong receive mode is selected. | • Select the correct receive mode. | p. 12 |
| • ATT function is activated. | • Release the ATT function. | p. 65 |
| • The [SQL] (RF gain) is set too far clockwise (when | • Turn the [SQL] (RF gain) counterclockwise. | p. 11 |
| USB, LSB or CW is selected). |
|
|
| • Batteries are nearly exhausted. | • Charge the batteries or place new dry cell batter- | p. 8 |
|
| ies in the battery case. |
|
|
|
|
|
Cannot tune frequency via | • Lock function is ON. | • While pushing [FUNC], push [(EDIT)LOCK] to turn | p. 64 |
the keypad or [DIAL] |
| the lock function OFF. |
|
|
|
|
|
Cannot charge the installed | • [CHARGE] is set to the OFF position. | • Set [CHARGE] to the ON position. | p. 8 |
|
|
| |
|
|
|
|
75