TROUBLESHOOTING 13

TROUBLESHOOTING 13

PROBLEM

POSSIBLE CAUSE

SOLUTION

REF.

 

 

 

 

Cannot start scanning.

• [SQL] is rotated too far clockwise.

• Rotate [SQL] counterclockwise.

p. 11

 

• Incorrect receive mode (LSB, USB or CW) is se-

• Set receive mode to one of FM, WFM or AM.

p. 12

 

lected.

 

 

 

• Scan edges are set to the same frequencies.

• Set scan edges to different frequencies.

p. 57

 

• 2 or more memory channels have not been pro-

• Program 2 or more memory channels.

pgs. 25,

 

grammed.

 

26, 27

 

• No channels have been programmed with the se-

• Program at least 2 channels with the selected re-

 

 

lected receive mode (when using mode select

ceive mode.

pgs. 25,

 

scan).

 

26, 27

 

 

 

 

Cannot recall memory

• Wrong operating mode is selected.

• Push [V/M] to select memory mode.

p. 23

channels.

 

 

 

 

 

 

 

WFM signal is distorted.

• Not tuned to the proper frequency.

• Set the frequency 30–50 kHz less.

p. 20

 

 

 

 

76