SECTION 11 : Error Messages Explained

 

Error Message

 

 

Description

 

 

Corrective Action

 

 

 

 

 

 

 

 

 

ERROR

 

 

The type of ribbon installed in theP-55

 

Replace the current ribbon with the same type of

 

 

 

is different from the

type

of ribbon

 

 

RBN-IMG Mismatch

 

 

 

ribbon as the one specified in the print data (*2) and try

 

 

 

specified in the print

data

(*2) sent

 

 

(*1)

 

 

 

printing again.

 

 

 

from your computer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERROR

 

 

Print data (*2) with unidentifiable

 

 

 

IMG Type too Old

 

 

ribbon type have been sent to the

 

Create print data (*2) using the latest printer driver.

 

(*1)

 

 

P-55.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You need to resend setdata to your P-55. To do so,

 

 

 

 

 

 

 

 

contact our service.

 

ERROR

 

 

Error occurred in the setdata that had

 

(For the contact details, see SECTION 20 : Contact

 

Invalid Setdata

 

 

been internally looked up during the

 

Information.)

 

(*1)

 

 

printer startup.

 

 

 

 

 

 

 

 

 

 

 

 

To clear the error message, open and then close the

 

 

 

 

 

 

 

 

side door. The printer is back in “Ready.”

(*1)---This error is indicated by the firmware Ver51.34 or later versions only.

(*2)---Print data is the file (PRN file (*3)) created using the function “Print to file” or the data to be output to a printer.

(*3)---For details on PRN file, see 9) Print to file” of SECTION 14 : Getting Label Print Job Started.