Fiber Signals: 16 feeder signals, max.; 432 distribution signals, max.

Adapters: SC/APC at cabinet end of fibers

Cross-Connect Bulkhead Positions: 6, max. Each bulkhead accommodates 72 X-connects (6 x 72 = 432)

Splitter Module Positions: 18, max. Each accommodates a 1x4, 1x8, 1x16 or 1x32 Telect Splitter Modules with front access installation and cabling. “Inputs” and “outputs” are 2-mm jumpers, 2.1 m long with SC/APC connectors

Parking Positions: 72, max., to accommodate unassigned split- ter “outputs”

Cabinet Material: 0.125 in, 5052 Aluminum

Cabinet Finish: Powder-coat almond

30.74 [780.9]

24.87 [631.7]

27.86 [707.7]

0.64 [16.2]

18.94 [481.0]

18.00 [457.2]

67.79 [1721.9]

2.72 [69.1]

24.92 [633.0]

28.31 [719.0]

51.24 [1301.4]

Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700

 

Poland +1.48.713.239.100 • UK +1.44.1489.889500 • www.telect.com