Acorn Nuts (3) Secure Patch
Module to Rear Wall of Partition
Patch Module
Bulkhead Swings on Hinge to Allow Access to Rear Connectors and Adapters From Front Compartment
Installing Model
FEEDER CABLE INSTALLATION
The cabinet accommodates up to 16 strands of OSP feeder cable. Telect supplies two cable clamps that accommodate cables between 3/8 in. (9.6 mm)
and 11/5 in. (30.5 mm) in diameter. Each clamp, shown on the right, uses several layers of gasket or bushing leaves to hold the cable fast between the two
halves of the clamp.
OSP cable can be dry or wet, armored or unarmored. To connect to adapters in the cabinet the incoming feeder fiber needs to be spliced to fiber strands with SC/APC connectors.
To install a feeder cable, proceed as follows:
1.Open rear door.
Leaves are provided in an onion skin roll to accommodate multifiber cabling from .375 in. to 1.25 in. (9.5 mm to 32 mm) in dia
OSP Cable
Bushing Leaves