2.Remove cable entrance dock at bottom of cabinet by removing six sets of nuts and washers shown in the following illustrations.

The cable entrance dock contains eight slots with slide-out cover plates. Each slots can accommodate two cable clamps for ei- ther feeder or distribution cable.

3.Slide out cover plate over feeder stub up.

4.Fish feeder cable into cabinet and then remove at least 15 ft (~5 m) of sheathing from the cabinet end.

NOTE

15 ft allows the feeder fiber to reach the furthest splice cassette. Break out more buffer/subunit if you intend to splice anywhere but at ground level at the open rear door. Add multiples of 8½ ft (~2.5 m) when adding to this length if the splicing is done, for example, in a vehicle. The multiple represents the perimeter around the splice box for storing the excess length of tubing.

Distribution Tie-Down Wall

Tie-Down Wall for

Incoming Feeder &

Distribution Fiber in

Loose Tubing

Chock Bar

Cover Plates

Cable Entrance Dock

Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700

 

Poland +1.48.713.239.100 • UK +1.44.1489.889500 • www.telect.com

Page 4-4

Copyright © 2002 Telect, Inc., All Rights Reserved