Section 3

Specifications

Switches and LED Indicators

Toggle switches and LED indicators are provided for installation, configuration, and troubleshooting.

Switch controls: AC power ON-OFF

Battery ON-OFF

LED Indications: LED 1: AC Power/Battery Condition LED 2: Cellular Connection Status

Power Supply

The switching power supply is designed to operate from a wide range of AC input voltages and is isolated against voltage transients.

AC power input:

90 to 277 VAC,

 

50 to 60 Hz

DC power input:

100 to 150 VDC

Output DC voltage:

13.2 volt DC +/- 5%, full

 

load

Maximum output current:

2.0 amperes

Power consumption:

Idle: 1.3 Watts

 

Transmit @ 3 Watts: 16.5

 

Watts

Primary to secondary insulation:

8,000 volts peak at 60 Hz

Battery charge voltage:

13.8 Volts

Input AC fuse rating:

2 amps Slow Blow, 250V

Primary surge protection:

1500 Watt-seconds

Secondary surge protection:

20 KvA

OMEGA Installation, Operation, and Maintenance Manual

33

Page 33
Image 33
Telenetics OM-AMPS-100 manual Switches and LED Indicators, Power Supply