IMPORTANT: Be sure the nut is aligned with the top of the OMEGA enclosure. If the nut is not parallel to the top of the enclosure, the OMEGA top cover will not close completely.

Connecting the Input Voltage Source

The following procedure describes how to connect OMEGA to an input voltage source of 90 - 277 VAC. When making this connection, use a UL-listed and approved power cord with a rating of 10 amps or above.

The OMEGA enclosure is pre-drilled with a hole that is .875 inches in diameter. This hole is used to accommodate a standard AC power cord and the conduit for the power cable running between the power source and the OMEGA unit.

1.Lift the AC fuse connector to turn off AC power to OMEGA (see Figure 1-1 on page 13). Do not close this AC fuse connector when connecting the input voltage source.

2.Insert the power cord through the conduit hole at the bottom of the compartment (see Figure 1-3).