48 Section 5
Input Setting Related to Input Level
Input Setting | 0dBu | +4dBu | +9dBu PPM | ||
|
|
|
|
|
|
Analog input level | - 10 dBV nom | 0 dBu nom | +4 dBu nom | +9 dBu PML | n/a |
|
|
|
|
|
|
Livewire/AES | - 32 dBfs nom | ||||
|
|
|
|
|
|
The ballistic (time) characteristic of Nx12’s meters changes depending on the Input Level set- ting so to match the expected console meter type. When
The table above shows the level at the green/red transition on the NX12 meter. For VU, this is the nominal 0 value; for PPM, this is the Permitted Maximum Level (PML) value.
The | usual setting is +4dBu. The +9dBu PPM setting is intended for Euro analog installations. |
The |
If Livewire inputs are used, this should usually be set to +4dBu for the
Nominal Output Level
This adjusts the level of analog, AES, and Livewire outputs.
Output Setting Related to Output Level
Output Gain Setting | 0dBu | +4dBu | +9dBu PPM | ||
|
|
|
|
|
|
Analog output level | - 10 dBV nom | 0 dBu nom | +4 dBu nom | +9 dBu PML | n/a |
|
|
|
|
|
|
Livewire/AES | - 32 dBfs nom | ||||
|
|
|
|
|
|
Meter Mode
Selects the audio that will be indicated on the LED meters.
♦♦ 4 Studio Out – Each studio output goes to a meter, from the top down ♦♦ 4 Studio In – Each studio input has a meter, from the top down
♦♦ POH in – The two Program on Hold inputs go to the top meters ♦♦ Phone 3&4 – Send and receive to/from hybrids 3 & 4
♦♦ Phone 1&2 – Send and receive to/from hybrids 1 & 2 ♦♦ Studio 3&4 – Input from and output to studios 3 & 4
♦♦ Studio 1&2 (default) – Input from and output to studios 1 & 2 (the meter markings correspond to this one)
Phone Send Adjustment
This setting adjusts the level of the hybrid into the telephone line, after the send limiter and is calibrated with 0dB representing the usual send level into the line.
The default is 0dB, which should be OK for most telephone lines. If callers consistently com- plain about low audio level and you have verified that this is a problem, you can increase the