24  Section 2

ing it from the output to the +5v source on pin 8. An appropriate value is 2.2kΩ.

♦♦ Sink (pull-down) current must be limited to 400mA maximum per output with total output restricted to 1 amp (200mA each output if all five will be used).

If you want to drive a relay, lamp, or high-current LED, you will need an external power source. Connect your external power source negative to Nx12 ground at pin 1 and positive to the relay. The other side of the relay goes to the output pin. (The Nx12’s +5v output is fed through a 100Ω resistor and a 50mA fuse, so cannot source much current.)

2.11 AC (mains) Power

The AC receptacle connects mains power to the unit with a standard IEC (International Electrotechnical Committee) power cord and provides an on/off switch. The power supply has a universal AC input, accepting a range from 100 to 240 VAC, 50-60 Hz.

IMPORTANT SAFETY INFORMATION

Surge Protection

Precautions should be taken to prevent damage caused by power surges. Standard line surge protectors can be used to offer some degree of protection. It is the user’s responsibility to ensure that protection adequate for their conditions is provided.

Grounding

This equipment is designed to be operated from a power source which includes a third ground- ing connection in addition to the power leads. Do not defeat this safety feature. In addition to creating a potentially hazardous situation, defeating this safety ground will prevent the internal line noise filter from functioning.

Page 34
Image 34
Telos NX12 user manual AC mains Power, Surge Protection, Grounding