80  Section 6

Condition: Intermittent ISDN Problems

These are among the most difficult kinds of problems to solve. Rest assured, however, that we have yet to lose one!

First try disconnecting the ISDN line and waiting a full 60 seconds (leave the Nx12 on) and then reconnect the line.

Does the problem occur on all of the ISDN BRI circuits or just a single BRI circuit (2 “lines”)?

If the problem is limited to a single BRI circuit (ie both “lines” on that BRI are showing the problem) then the problem may be with that BRI line or with that ISDN interface card. Move the BRI line in question to a different interface card (don’t forget to reprogram the SPIDs).

If the problems moves it must be with the BRI itself. If it remains with certain “lines” on the system then it is probably in the ISDN interface card. Swapping cards between two of the interface slots will confirm or disconfirm this.

If the NT1 sync light for a given ISDN BRI circuit occasionally cycle to the fast flashing state, then the line or NT1 is marginal.

If the problem occurs on 2 BRI circuits simultaneously, and they are both in the same interface slot, then it is likely the problem is with that ISDN interface card. Swapping cards between two of the interface slots will confirm or disconfirm this.

Are the problem confined to incoming call only?

In this case, check the ISDN (Telco) protocol setting in the TEL. If you believe your line is DMS Custom try the National ISDN setting, or vice versa.

Are the DNs entered correctly? If so, try using 10 digits rather than 7 digits, or vice versa.

What is consistent about the problem (look for patterns)?

Keep watching for a pattern. Enlist the help of the users. We’ve seen apparently random prob- lems that we eventually discovered only occurred when it rained, or on a certain day each week, or at a certain time of day, or only when another line was in use. In other cases, it was related to temperature or dirty AC power. Assume nothing and suspect everything. Leave no stone unturned while searching for the answer.

Any other ISDN troubleshooting tips?

An important tool for troubleshooting incompatibility/programming problems is the Nx12’s integrated ISDN analyzer. This enables you to look at the transactions between the Telco line and the Nx12, so that a judgment can be made as to whether the problem lies within the Nx12 or with the programming of the Telco switch.

The usual cause of inability to dial problems is a Telco problem, such mis-programming.

If you are convinced that the problem lies with the ISDN line configuration, you may be able to convince the Telco to have an engineer look at the line with an analyzer. This works much like the Nx12’s internal analyzer, but with more detail, and in a format that is more readily under- standable by telephone people. This procedure may sometimes be the only way to get attention to a line problem. It is hard to deny evidence provided by their own gear.

In rare cases, there could be a software bug in the Nx12 that reacts badly to something coming from the ISDN line. Telos customer support will communicate the problem to our engineering guys for resolution. See Section 7.41 for information on connecting to the Nx12’s command line

Page 90
Image 90
Telos NX12 user manual Condition Intermittent Isdn Problems, Are the problem confined to incoming call only?