3. After insert liner between the see through type gap sensor, press the
button under V icon to continue.
4. Press the button under + icon to increase Stock AD value by
50 increment. And press the button under V icon to calibrate
the sensor sensitivity.
4.1.2.1.2 Manual Gap:
If Auto Gap sensor calibration can not apply to the media, please use
Manual Gap function to calibrate sensor manually. This function can be
used to fine tune sensor sensitivity. When enter [Manual Gap] option,
you will see following message.
Stock AD on liner Stock AD on paper
Press the button under + and - to increase and decrease
sensor intension, and press the under V to set the value to
printer.
When adjust the sensor sensitivity manually, we can get the different
Stock AD on liner and paper in each sensor intension. The difference
between these two values must be larger than 50 levels then printer
can register label position correctly.
GAP Calibrate
185
+ - V
Gap Sensor
Stock AD = 50
Intension = 140
+ - V
Gap Sensor
Stock AD = 163
Intension = 140
+ - V