When enter the [Continuous] option, you will see following message.

Insert label ...

Then hit Enter

V

Insert media between the gap sensor and press the button under “V” icon to

start sensor calibration

Calibrate 50

+ - V

Press the button under “+” and “-“ icon to increase and decrease

Stock AD value, and press the under “V” icon to detect sensor sensitivity.

Calibrating ...

Stock AD = 256

SUCCESSFUL

Stock AD = 50

Press the button under “” icon to return to the next higher menu.

If “FAILED” is shown on the LCD display, please check if the media is placed between the see through type gap sensor.

FAILED

Stock AD = 50

If yes, please follow the following steps to calibrate sensor sensitivity agian.

1.Press the button under “” icon to return to “Sensor” menu.

2.Press the button under “]” icon to enter “Continuous” menu.

3.After insert label between the see through type gap sensor, press

the button under “V” icon to continue.

4.Press the button under “+” icon to increase Stock AD value by

50 levels. Press the button under “V” icon to calibrate the sensor

32

Page 35
Image 35
The Speaker Company M23 user manual Calibrate