8. Firmware Update Procedure

Both RS-232 and USB interfaces are available to upgrade printer firmware. Please refer to the firmware update procedures as below.

8.1 Update Firmware Via Serial Port

1.Set M23’s “Serial Comm.” setting as below. Baud Rate = 115200

Parity = No Parity Data Bits = 8 Data Bits Stop Bits = 1 Stop Bits

2.Printer is in ready mode.

Ready

ll

Method 1In MS-DOS mode (Command Prompt), copy the firmware file (*.NEW) to printer via serial port.

(1) Set the PC’s COM port setting.

Please issue following command in command prompt mode to setup PC RS-232 communication parameters.

C:\>mode com1 baud=115200 parity=n data=8 stop=1 octs=on rts=on <Enter>

(2)Copy firmware file to M23 with binary copy parameter. C:\>copy M23_v06.NEW /b com1

58

Page 61
Image 61
The Speaker Company M23 user manual Firmware Update Procedure, Update Firmware Via Serial Port