4. BLOWER MOTOR SPEED WIRING

All installations and services must be performed by qualified service personnel.

mounted junction box. The hot leg must pass through the disconnect switch in all cases to prevent the hazard of electrical shock when servicing.

IMPORTANT: The furnace must be grounded in accordance with local codes and with the National Electrical Code, ANSI/NFPA NO. 70 (Latest Edition) when an external electrical source is utilized.

4. BLOWER MOTOR SPEED WIRING

Figure 15.

BLOWER DELAY SETTINGS

To delay fan turn-on by:

15sec.

30sec.

*45 sec.

60 sec,

 

Set Switch

#1

#2

Off

Off

Off

On

On

Off

On

On

To delay fan

Set Switch

turn-off by:

#3

#4

60 sec.

On

On

90 sec.

Off

On

*120 sec.

On

Off

180 sec.

Off

Off

*Factory Settings For Optimal Performance