1. OPERATIONS BEFORE IN-LINE SERVICE EO1-11138

1-3

1.3 Terminal Condition Check
Journal Print

1.3 Terminal Condition Check

This operation checks the condition of the designated terminals, and prints out the status responded from the

terminals.

CONDITION Any time outside a sale (operable on Master Terminal)

OPERATION Mode Lock: X and RTR Declaration ON

Through the Operator Display

Select “5 OTHERS”. Select “81 T/M CHK”.

P00 T/M DESIGN#04 #3003 0189 09:26TM
*X/GTX* 02-06-1999 03:04
RTR
1 X
2 GTX
3 PROGRAM READ
4 E-JOURNAL
5 OTHERS
Please select operation by Enter key.
0.00
TOTAL
0.00
COMB1 COMB2 COMB3 EJ
*X/GTX* 02-06-1999 03:04
OTHERS RTR
80 T/M OPEN CHK
81 T/M CHK
82 PRT CHECK
90 CONSOLI READ
98 FILE VER CHK
99 INLINE LOG
Please select operation by Enter key.
0.00
Pg up Pg dw Enter
→
Through the Keyboard
81 [AT/TL]
Master Terminal Receipt Print
12-25-1999 SAT
#3001
****************************************
****************************************
********************
X81
T/M_CHECK
#3001 OK
#3002 NO RESPONSE
#3003 NO RESPONSE
****************************************
****************************************
********************
0191 09:42TM
Status SymbolOK: The terminal condition is normal.NO RESPONSE: No response (power-OFF, etc.)
Blank: Other statuses